Buyer access is for device lookup and self-check. Inspector access is limited to authorized staff; it does not by itself issue a certification report.
Illustrative scene created with AI, not a photograph of the actual device or inspection. Refer to the issued device report for inspection evidence.
What this page means
A proposed phone protocol, not an automatic certificate.
The 68 slots describe the phone checklist structure. Reports must show the applicable total, tested count, pass/fail, not-tested count and reasoned N/A. A badge can appear only after real inspection, evidence review and a released device report. Tablets and earphones require device-specific appendices before they can use a released standard.
Nimall Certified is Nimall’s documented inspection framework. It is not a government, manufacturer, authorized-service or third-party certification.
PHONE OPERATING STANDARD · V0.2 PROPOSED
68 checklist slots across 9 modules.
Open a module to see every checkpoint, method, pass condition and evidence requirement.
68checklist slots9 modules
01Identity & provenance8 checksConfirms the device identity, lawful source and absence of undisclosed ownership or management locks.Examples:ID01 · Model and regional variant; ID02 · Serial and internal IMEI consistency; ID03 · Storage capacityView all checksHide checks⌄
ID01
Model and regional variant
Method
Compare Settings/About, chassis label and intake record.
Pass condition
Model and regional variant agree; target-market relevance is recorded.
Evidence required
Settings capture and exterior label photo.
ID02
Serial and internal IMEI consistency
Method
Compare system identifiers with available chassis, tray and intake references.
Pass condition
Identifiers are internally consistent; any mismatch is HOLD.
Evidence required
Masked identifier captures from each available source.
ID03
Storage capacity
Method
Read system-reported total capacity and compare it with the intake listing.
Pass condition
Recorded and system-reported capacity agree.
Evidence required
Storage settings capture and intake reference.
ID04
Supplier invoice and chain of custody
Method
Review the supplier invoice, intake party, dates and internal hand-offs.
Pass condition
A traceable source and custody record exists with no unresolved gap.
Evidence required
Restricted internal invoice and custody references; not public.
ID05
Available blacklist or loss check
Method
Query an approved available source and record source, date and coverage.
Pass condition
No adverse result within the documented scope; scope limits are disclosed.
Evidence required
Dated internal lookup reference and source name.
ID06
Activation Lock or FRP cleared
Method
Connect to a network and complete normal activation without bypass; remove test accounts before release.
Pass condition
No former-owner credential is required and the final reset is rechecked.
Evidence required
Activation steps, reviewer record and final setup-screen evidence.
ID07
Carrier or SIM lock and market compatibility
Method
Read lock status and use a target-market SIM where available.
Pass condition
Lock status is disclosed and target-market compatibility is confirmed or HOLD.
Evidence required
Settings capture plus SIM registration or call record.
ID08
MDM, finance or remote-management restrictions
Method
Inspect management profiles, enrollment prompts and activation restrictions.
Pass condition
No active MDM, finance or remote-management restriction may limit ownership or normal use; any active restriction is HOLD/FAIL even if disclosed.
Evidence required
Profile/settings captures and activation notes.
02Cosmetic condition7 checksRecords measured visible wear separately from functional eligibility and safety decisions.Examples:CO01 · Screen glass scratches or cracks; CO02 · Rear cover condition; CO03 · Frame and cornersView all checksHide checks⌄
CO01
Screen glass scratches or cracks
Method
Clean the screen; inspect under fixed lighting and distance; count and measure defects.
Pass condition
No crack; scratches are measured, photographed and assigned to the actual grade.
Evidence required
Front photos under consistent light with scale reference.
CO02
Rear cover condition
Method
Inspect the cleaned rear surface under fixed lighting; count and measure wear.
Pass condition
No unsafe breakage or lifting; visible wear is graded and disclosed.
Evidence required
Rear photos with close-ups and scale where needed.
CO03
Frame and corners
Method
Inspect all edges and corners; record dents, chips and lengths.
Pass condition
No structural deformation; measured wear matches the stated grade.
Evidence required
Four-edge and four-corner photo set.
CO04
Camera cover condition
Method
Inspect every lens cover under angled light and verify image impact.
Pass condition
No crack or obstruction affecting capture; marks are disclosed.
Evidence required
Lens-cover close-ups and matching test images.
CO05
Seams, bending or lifting
Method
Check panel seams and flatness visually and with a straight reference.
Pass condition
No bending, separation or lifting; any such finding is HOLD or FAIL.
Evidence required
Edge-profile photos and measured gap notes.
CO06
Screws and repair-entry evidence
Method
Inspect screw heads, seams and tool marks for prior opening evidence.
Pass condition
Evidence is recorded; unresolved repair source or safety concern is HOLD.
Evidence required
Macro photos and repair-disclosure reference.
CO07
Ports, grilles and tray exterior
Method
Inspect ports, grilles and SIM tray for damage, debris and deformation.
Pass condition
No hazardous damage or obstruction; cosmetic wear is disclosed.
Evidence required
Close-up photos before and after safe cleaning.
03Display & touch8 checksChecks pixels, burn-in, brightness, touch coverage and display-related parts disclosures.Examples:DT01 · Dead or stuck pixels; DT02 · Burn-in or persistent image; DT03 · Brightness and uniformityView all checksHide checks⌄
DT01
Dead or stuck pixels
Method
Show black, white, red, green and blue full-screen patterns in a dim controlled area.
Pass condition
No visible dead or stuck pixel under the documented method; findings are measured.
Evidence required
Five screen photos and test pattern/version reference.
DT02
Burn-in or persistent image
Method
Display neutral grey and solid fields after normal use and observe persistence.
Pass condition
No persistent ghost image visible under the recorded setup.
Evidence required
Grey-field photo and observation time.
DT03
Brightness and uniformity
Method
Check low, mid and maximum brightness on a neutral field.
Pass condition
Brightness changes smoothly with no abnormal flicker or severe non-uniformity.
Evidence required
Photos at three levels and reviewer note.
DT04
Full-screen touch grid
Method
Trace every cell and edge of a controlled touch-grid test.
Pass condition
Every required cell records the trace with no gap or dead zone.
Evidence required
Completed grid capture and tool/version reference.
DT05
Multi-touch
Method
Use a controlled multi-touch tool and record simultaneous contacts.
Pass condition
The device records the expected contacts for its supported design.
Evidence required
Tool capture showing contact count.
DT06
Ghost touch
Method
Observe idle screens, typing and repeated drags for uncommanded input.
Pass condition
No uncommanded touch or repeated unexpected movement is observed.
Evidence required
Timed observation notes and video if a fault appears.
DT07
Brightness adjustment and auto mode
Method
Move the brightness control and test auto response where the model supports it.
Pass condition
Manual control works; supported auto mode responds to controlled light change.
Evidence required
Control captures and supported-feature note.
DT08
Display parts warnings and features
Method
Review parts/service history and verify advertised display features.
Pass condition
Warnings and replaced-display limits are disclosed; unresolved source or safety is HOLD.
Evidence required
System-history capture and feature-test notes.
04Battery & charging8 checksUses supported readings and controlled raw tests; missing validated baselines never become an automatic pass.Examples:BC01 · Battery health percentage; BC02 · Cycle count where available; BC03 · Swelling and thermal safety stopView all checksHide checks⌄
BC01
Battery health percentage
Method
Read a supported numerical health value and record tool or system path and date.
Pass condition
At least 85% for an eligible phone with a validated reading; otherwise UNVERIFIED/HOLD.
Evidence required
Dated system/tool capture with method version.
BC02
Cycle count where available
Method
Read the manufacturer-supported cycle count field when the model exposes it.
Pass condition
Value is recorded exactly; never estimated. A natively unsupported field may be N/A with evidence.
Evidence required
System capture or documented unsupported-state evidence.
BC03
Swelling and thermal safety stop
Method
Inspect for swelling and monitor abnormal heat during controlled charging and workload.
Pass condition
No swelling or unsafe thermal behaviour; any concern stops testing and blocks release.
Evidence required
Exterior profile photos and temperature method/raw notes.
BC04
Wired charging stability
Method
Charge with a known-good compatible cable and adapter while observing connection stability.
Pass condition
Charging remains stable without repeated disconnects or unsafe heat.
Evidence required
Accessory IDs, start/end percentage and observation notes.
BC05
Wireless charging where supported
Method
Use a known-good compatible pad and verify a stable charging session.
Pass condition
Supported wireless charging starts and remains stable; unsupported design is N/A with evidence.
Evidence required
Pad ID, model support reference and charge capture.
BC06
Fixed 20-minute workload raw record
Method
Run the approved non-destructive workload; record raw start/end percentage and temperature.
Pass condition
Only passes against an approved model baseline and temperature method; missing baseline is HOLD.
Evidence required
Shared raw workload log with PS04, timestamps and model baseline version.
BC07
Fixed 30-minute idle raw record
Method
Leave the device in the approved idle state; record raw start/end percentage and temperature.
Pass condition
Only passes against an approved model baseline; missing baseline is HOLD.
Evidence required
Timed idle log, environment note and baseline version.
BC08
Battery parts or service warnings
Method
Review manufacturer parts/service messages and battery warnings.
Pass condition
Verified replacement is disclosed; unresolved source or safety is HOLD, not labelled counterfeit.
Evidence required
System-warning capture and repair evidence reference.
05Cameras, audio & sensors12 checksExercises each available camera, audio path, core sensor and haptic function.Examples:CA01 · Each rear camera still capture; CA02 · Front camera still capture; CA03 · Near and far autofocusView all checksHide checks⌄
CA01
Each rear camera still capture
Method
Select every available rear camera and capture the same controlled near and wide scene.
Pass condition
Every advertised rear camera captures a clear file without error.
Evidence required
Original test images labelled by camera.
CA02
Front camera still capture
Method
Capture a controlled well-lit image with the front camera.
Pass condition
Front camera opens, focuses and saves a clear image.
Evidence required
Original front-camera test image.
CA03
Near and far autofocus
Method
Tap-focus on near and far reference targets with each focusing camera.
Pass condition
Focus moves and settles clearly at both distances without repeated hunting.
Evidence required
Near/far images and short focus video if needed.
CA04
Video record and replay
Method
Record a timed clip with movement and sound, then replay it on the device.
Pass condition
Recording saves and replays with synchronized visible image and audio.
Evidence required
Original clip and duration reference.
CA05
Flash
Method
Capture with flash in a controlled low-light scene.
Pass condition
Flash fires consistently and the resulting image is usable.
Evidence required
Low-light before/after images.
CA06
Microphones
Method
Record voice memo and video samples from the available microphone paths.
Pass condition
Speech is intelligible without severe dropout or distortion.
Evidence required
Original audio/video samples and path notes.
CA07
Loudspeaker
Method
Play a controlled reference tone and spoken sample at moderate levels.
Pass condition
Output is clear across the tested range without severe rattle or dropout.
Evidence required
Reference-file ID and observation note.
CA08
Earpiece through a test call
Method
Place a controlled test call and listen through the earpiece.
Pass condition
Speech is intelligible and stable during the call.
Evidence required
Masked call log and operator note.
CA09
Proximity sensor
Method
During a test call, cover and uncover the sensor area.
Pass condition
Display turns off near the face and returns when uncovered.
Evidence required
Short test note or video.
CA10
Ambient light sensor
Method
Expose the sensor to controlled darker and brighter conditions with auto brightness enabled.
Pass condition
Supported auto brightness responds in the expected direction.
Evidence required
Light-condition and screen-response notes.
CA11
Accelerometer and gyroscope rotation
Method
Rotate the device through portrait and landscape in a supported app.
Pass condition
Orientation changes consistently without freezing or uncontrolled movement.
Evidence required
Rotation sequence note or video.
CA12
Haptics
Method
Trigger supported keyboard, notification and system haptic events.
Pass condition
Expected haptic events are present and consistent without abnormal noise.
Evidence required
Event list and operator observation.
06Connectivity8 checksTests target-region network use with controlled setups, without promising laboratory throughput.Examples:CN01 · SIM registration and two-minute test call; CN02 · Mobile data; CN03 · Available Wi-Fi bandsView all checksHide checks⌄
CN01
SIM registration and two-minute test call
Method
Insert a compatible target-market SIM, register to network and complete a two-minute call.
Pass condition
Registration and the timed call remain stable. Missing setup is NOT TESTED/HOLD.
Evidence required
Masked network and call record.
CN02
Mobile data
Method
Load a controlled page or file over the registered mobile network.
Pass condition
Data session completes without repeated disconnect; no speed promise is made.
Evidence required
Network type, time and test reference.
CN03
Available Wi-Fi bands
Method
Connect to each available controlled band supported by the device.
Pass condition
Supported available bands connect and exchange data; capability limits are recorded.
Evidence required
Access-point IDs, band and connection result.
CN04
Bluetooth pairing and audio
Method
Pair with a known-good audio device and play a reference sample.
Pass condition
Pairing, connection and audio remain stable.
Evidence required
Accessory ID and pairing/audio notes.
CN05
Outdoor GNSS fix
Method
In an open outdoor area, request a location fix and record time and conditions.
Pass condition
A stable fix is obtained within the approved model method; no laboratory accuracy claim.
Evidence required
Timestamp, environment and diagnostic capture.
CN06
NFC with a known test tag
Method
Read a known non-payment NFC test tag where supported.
Pass condition
Supported NFC reads the tag consistently; no payment transaction is attempted.
Evidence required
Tag ID and read-result capture.
CN07
Hotspot
Method
Enable hotspot and connect one controlled client for a short data exchange.
Pass condition
Client connects and completes the controlled exchange.
Evidence required
Client ID, time and test reference.
CN08
Dual-SIM or eSIM when advertised
Method
Activate and switch between advertised SIM paths using approved test service where available.
Pass condition
Advertised and testable SIM paths register correctly; missing setup is NOT TESTED/HOLD.
Evidence required
SIM-path captures and service/setup reference.
07Buttons, ports & biometrics6 checksChecks repeated physical controls, data transfer and controlled biometric unlocks.Examples:BP01 · Power and volume buttons; BP02 · Mute, action or home control; BP03 · USB port and data transferView all checksHide checks⌄
BP01
Power and volume buttons
Method
Press power, volume up and volume down ten times each.
Pass condition
Every press produces the expected response with no sticking or missed input.
Evidence required
Count sheet and operator note.
BP02
Mute, action or home control
Method
Operate each native supported control repeatedly and observe the system response.
Pass condition
Each supported control responds consistently; unsupported native feature may be N/A with evidence.
Evidence required
Control list and response capture.
BP03
USB port and data transfer
Method
Connect to a controlled host and copy a nonpersonal test file in both directions.
Pass condition
Connection remains stable and the file hash matches after transfer.
Evidence required
Cable/host IDs and before/after file hash.
BP04
Physical audio connector where supported
Method
Connect known-good wired audio equipment and play/record a reference sample.
Pass condition
Supported connector outputs and, where designed, inputs audio correctly.
Evidence required
Accessory ID and audio observation.
BP05
Fingerprint unlock 5 of 5
Method
Enroll a test finger and perform five controlled unlock attempts.
Pass condition
Five of five valid attempts unlock; enrollment is deleted before final reset.
Evidence required
Attempt log and deletion confirmation.
BP06
Face unlock 5 of 5
Method
Enroll a test face and perform five controlled valid unlock attempts.
Pass condition
Five of five valid attempts unlock; enrollment is deleted before final reset.
Evidence required
Attempt log and deletion confirmation.
08Performance & software5 checksRecords repeatable boot, software, storage and workload observations without overstating their scope.Examples:PS01 · Boot and restart three cycles; PS02 · OS version, update and support status; PS03 · Storage write and read testView all checksHide checks⌄
PS01
Boot and restart three cycles
Method
Complete three full boot or restart cycles and record each duration and outcome.
Pass condition
All three cycles reach the normal usable state without crash or loop.
Evidence required
Three-cycle timing log.
PS02
OS version, update and support status
Method
Record installed OS, available update result and manufacturer support information at the test date.
Pass condition
Version and support status are accurately disclosed; no future support promise.
Evidence required
Dated settings captures and source reference.
PS03
Storage write and read test
Method
Write and read a controlled nonpersonal test file and compare its hash.
Pass condition
The limited test completes with matching hash; it is not a full-chip guarantee.
Evidence required
File size, timing and before/after hash.
PS04
Controlled 20-minute workload
Method
Run the approved app/camera workload while recording crashes, restarts and raw battery/temperature data.
Pass condition
No crash or reboot; battery/thermal pass still requires an approved model baseline.
Evidence required
Shared raw workload record with BC06.
PS05
Data wipe and former-account check
Method
Perform normal erase, verify setup state, then connect and activate to check prior-owner locks; erase test accounts again.
Pass condition
No former account or file remains and no lock appears during normal activation; not forensic-certified erasure.
Evidence required
Erase steps, activation result and final re-erase record.
09Safety & report release6 checksApplies safety stops, independent review and the final device-to-report match before dispatch.Examples:SR01 · Visible liquid or corrosion indicators; SR02 · Supplied accessory safety; SR03 · Repair history and parts disclosuresView all checksHide checks⌄
SR01
Visible liquid or corrosion indicators
Method
Inspect accessible indicators and visible corrosion without immersion or destructive opening.
Pass condition
No unresolved liquid/corrosion safety concern; no water-resistance recertification claim.
Evidence required
Indicator/corrosion photos and access limitation note.
SR02
Supplied accessory safety
Method
A competent operator identifies supplied accessories and checks condition, compatibility and visible electrical safety.
Pass condition
No unsafe or unidentified supplied electrical accessory is released.
Evidence required
Accessory IDs, ratings and condition photos.
SR03
Repair history and parts disclosures
Method
Review manufacturer history, system warnings and available repair evidence with stated limitations.
Pass condition
Verified repairs are disclosed; unknown warning is not called counterfeit and unresolved risk is HOLD.
Evidence required
System captures and restricted evidence reference.
SR04
Device-specific photos and report match
Method
Compare masked identifiers, distinguishing marks and required photo set with the draft report.
Pass condition
The report and evidence belong to the same device with no unexplained mismatch.
Evidence required
Reviewer comparison checklist and photo index.
SR05
Independent reviewer sign-off
Method
A reviewer separate from the initial inspection checks critical gates, evidence completeness, version and time.
Pass condition
Reviewer resolves every HOLD and signs the internal release record; score cannot override a critical fail.
Evidence required
Internal reviewer ID, timestamp and protocol version.
SR06
Final pre-dispatch recheck and seal
Method
Recheck identity, activation state, physical condition, included items and report match immediately before dispatch.
Pass condition
Device still matches the released report and is sealed without test accounts or biometrics.
Evidence required
Dispatch checklist, seal reference and timestamp.
Recorded outcomes
Pending is not N/A.
Every applicable check ends with a visible consequence. A score never compensates for a critical safety, security or source failure.
Pass
The recorded evidence meets the stated condition.
Disclosed
A cosmetic condition or verified repair fact is shown separately; disclosure does not erase a functional gate.
Fail
The condition is not met. A critical fail blocks release.
N/A
Only for a feature the device was not designed to have, with device evidence.
Not tested / evidence missing
HOLD. No badge or released report until the gap is resolved.
Critical safety, security or source fail = ineligible. Score cannot override it.
Illustrative scene created with AI, not a photograph of the actual device or inspection. Refer to the issued device report for inspection evidence.
Two decisions
Function tested. Condition explained.
Functional gates and cosmetic findings are recorded separately. Any future A/B/C grade must still pass all applicable functional and safety gates.
Every visible defect is counted or measured and photographed under a controlled lighting, distance and scale setup. A/B/C calibration thresholds are pending pilot validation, so no production grade is issued from this Preview.
A
Proposed A band
The lowest-wear band. The report must still list each measured mark; cracks, bending and lifting are never permitted.
B
Proposed B band
A middle measured-wear band to be calibrated in the pilot. Exact counts, lengths and photos remain visible to the customer.
C
Proposed C band
The highest eligible measured-wear band to be calibrated in the pilot; it never permits a structural or safety failure.
Cracks, bending or panel lifting are HOLD/FAIL—not merely a lower cosmetic grade.
85%Battery health
Nimall proposed phone threshold
A number only counts when the method is validated.
For an eligible phone, 85% is Nimall’s proposed minimum battery-health threshold—not an Apple or Samsung standard. If a reliable numerical method is unavailable, the device stays HOLD.
BC06 and PS04 may share one raw 20-minute workload record. BC06/BC07 raw percentages and temperature do not auto-pass without an approved model baseline and measurement method.
Operating workflow
No badge before inspection and independent review.
Real inspection and review must be completed by people. The page and template do not create a valid report or QR code.
1
Intake, identity & safety
Register the device, source evidence and immediate safety stops.
2
Inspection
Run applicable checks with controlled tools and raw records.
3
Repair & retest
Disclose verified work; resolve or retain HOLD items.
4
Independent review
A second reviewer checks critical gates and evidence.
5
Device report
Release only a device-specific, privacy-filtered report.
6
Dispatch
Recheck identity, reset state, included items and seal.
7
Return & reinspection
Reopen the record and inspect again before any new release.
Required setup
Controlled tools and per-unit records.
The exact equipment list must be approved for each model family and site before operations begin.
Known-good compatible cables, adapters, chargers and test accessories
Controlled SIM, Wi‑Fi, Bluetooth, NFC tag and nonpersonal test files
Five-colour display patterns, touch-grid and supported manufacturer diagnostics
Consistent lighting, distance, scale references and camera capture
Approved temperature measurement method and model baselines
Restricted custody/repair evidence store plus independent reviewer account
Device report design
A released report belongs to one inspected device.
Public output contains masked identifiers and an internal inspector code. Full IMEI, invoices, signatures and personal data stay restricted.
01
Masked identity
What is recorded
Recorded: model, region, storage and masked serial/IMEI.
How it is obtained
Obtained: system settings and matched intake references.
What the customer sees
Customer sees: masked values and match status only.
Why it matters
Why it matters: prevents a generic model report being reused.
02
Parts & repair
What is recorded
Recorded: verified repairs, warnings and evidence limits.
How it is obtained
Obtained: manufacturer history, system messages and available records.
What the customer sees
Customer sees: verified facts and unresolved limitations.
Why it matters
Why it matters: an “unknown” warning is not automatically counterfeit.
03
Photos & raw records
What is recorded
Recorded: required angles, measured defects and selected raw logs.
How it is obtained
Obtained: consistent capture setup and controlled tests.
What the customer sees
Customer sees: privacy-filtered device photos and relevant findings.
Why it matters
Why it matters: condition and results can be checked against evidence.
04
Inspection & review
What is recorded
Recorded: protocol version, timestamps and internal inspector/reviewer codes.
How it is obtained
Obtained: human inspection plus independent review.
What the customer sees
Customer sees: dates, version and masked staff codes.
Why it matters
Why it matters: shows which released procedure governed the result.
05
Report lookup status
What is recorded
Recorded: release status and report reference when a real backend exists.
How it is obtained
Obtained: not generated by this page or blank template.
What the customer sees
Customer sees: currently a SAMPLE process explanation only.
Why it matters
Why it matters: no QR or lookup capability is claimed before a real service exists.
SAMPLE · UNRELEASED
Example report structure — not a valid device report.
NO VALID REPORT
No real identifier, inspection, pass result or QR code is represented here. The fields below show how a future released record would separate counts and outcomes.
DeviceSample phone / masked ID ••••
Applicable slots
—
Tested
—
Passed
—
Failed
—
Not tested
—
N/A with reason
—
Public view never exposes full IMEI, supplier invoices, signatures or personal data.
Supporting operator templates
Blank records for human completion.
These files contain no passed results and do not issue a badge. A trained operator and independent reviewer must complete and approve the real record.